2-2
When mounting two or more inverters
Horizontal layout is recommended when two or more inverters are to be installed in the same unit or
enclosure. As long as the ambient temperature is 40°C or lower, inverters may be mounted
side-by-side without any gap between them. If it is necessary to mount the inverters vertically, install
a partition plate or the like between the inverters so that any heat radiating from an inverter will not
affect the one/s above.
(3) Mounting direction
Secure the inverter to the mounting base with four screws or bolts (M4) so that the Jaguar CUB logo
faces outwards. Tighten those screws or bolts perpendicular to the mounting base.
Do not mount the inverter upside down or horizontally. Doing so will reduce the heat
dissipation efficiency of the inverter and cause the overheat protection function to operate,
so the inverter will not run.
Prevent lint, paper fibers, sawdust, dust, metallic chips, or other foreign materials from getting
into the inverter or from accumulating on the heat sink.
This may result in a fire or accident.
2.3 Wiring
Follow the procedure below. (In the following description, the inverter has already been installed.)
2.3.1 Removing the Terminal Block (TB) Covers
(1) Removing the control circuit terminal block (TB) cover
Insert your finger in the cutout (near "PULL") in the bottom of the control circuit TB cover, then pull
the cover towards you.
(2) Removing the main circuit terminal block (TB) cover
Hold both sides of the main circuit TB cover between thumb and forefinger and slide it towards you.
Figure 2.2 Removing the Terminal Block (TB) Covers
Summary of Contents for Jaguar CUB
Page 47: ...3 5 Figure 3 2 Alarm Mode Status Transition...
Page 77: ...5 4...
Page 78: ...5 5 E codes Extension Terminal Functions...
Page 80: ...5 7...
Page 81: ...5 8 C codes Control Functions of Frequency...
Page 84: ...5 11 y codes Link Functions...
Page 149: ...8 5 8 3 Common Specifications...
Page 150: ...8 6...
Page 153: ...8 9 8 5 External Dimensions 8 5 1 Standard Models...
Page 154: ...8 10...
Page 155: ...8 11 8 5 2 Models Available on Order EMC Filter Built in Type...
Page 156: ...8 12...