E211101X_rev02_ENG
29/06/2022
10
ATTENTION!
The user must be aware and trained about the dangerousness connected with the tampering with conductions
and/or modification, obstructions, or ructions about the installation room ventilation openings.
Refer to the here attached technical data sheet for dimensions and quote about gas and humid air exhaust.
9.
ELECTRICAL CONNECTION
Electric connection must be conducted by qualified technicians and must comply with local and national rules in force.
Check the supply tension, it must comply with the label data on the ironer back. To connect the machine, please use a
cable H05 VV – F or more. The cable must be dimensioned following the here below section chart:
2500
2800
3200
Electric heating
5x25mm
2
5x25mm
2
5x25mm
2
Steam/gas heating
5x2,5mm
2
5x2,5mm
2
5x2,5mm
2
Before the ironer power supply line install a device for disconnection (i.e.: magneto thermal differential unit) with a
contact opening which allows the complete disconnection in case of the conditions of III category over tension are
verified, complying with the rules in force.
Be sure the main switch is in position “0”.
Open the side door using the key given with the ironer documents.
Take off the door paying attention that already connected cables are not pulled out.
Pass the cable through the cable holder on the ironer left side.
Electric supply must be done connecting the cable to the terminals mounted on the ironer: