Operation
Draco tera flex
292
9.6.8
Redundancy Function
Extender modules with redundant connectors for interconnect cables can be simultaneously operated with
both connectors at a single matrix or a matrix Grid (from firmware version V04.00).
The connector labeled with
Link 1
at the KVM extender is meant for the primary connection. If the
connection on CON Unit or CPU Unit side is interrupted due to any problem, the connection will be
automatically re-established through the second connector labeled with
Link 2
.
For this kind of redundancy function, there is no need for any configuration of the matrix or the extender
modules.
Fig. 222
Management software menu View - Matrix
To check the connection status of the redundant extender modules, proceed as follows:
1. Select
View > Matrix
in the task area.
2. Activate the checkbox
Show Redundant Links (L1/L2)
under
Routing Information
on the right side of
the working area.
3. Open the menu
Redundancy
on the right side of the working area to receive the respective legend
information.
4. Redundant connectors are highlighted in the matrix view with L1 and L2. The respectively active link is
highlighted with a light green label.