Draco tera flex
Configuration via Management Software
147
The following parameters can be configured:
Field
Entry
Description
Enable Video Sharing
Activated
The user can switch to any CPU Device as an observer,
including ones that are already assigned to another user
(observer without keyboard/mouse access).
Note:
Switching with the
<Space>
key, not with the
<Enter>
key.
The operator only will be informed if further users connect as an
observer to the CPU Device that is connected to his CON
Device, if the option
Update Connection Info
is activated for
his CON EXT Unit.
Deactivated
Function not active (default)
Force Connect
Activated
The user can connect to every single CPU Device as an
operator, including ones that are related to another user.
Note:
The previous user is set to Video Only status.
To share K/M control,
Force Connect
has to be activated.
Deactivated
Function not active (default)
Force Disconnect
Activated
Extension of
Force Connect
: If the user connects as an
operator to a CPU Device already related to another user, the
previous user will be disconnected.
Note:
To share K/M control
Force Disconnect
has to be
deactivated and
Enable Video Sharing
has to be activated.
Deactivated
Function not active (default)
CPU Auto Connect
Activated
If a CON Device is not connected to a CPU Device, you can
establish an automatic connection to the next available CPU
Device by hitting any key or mouse button.
Deactivated
Function not active (default)
CPU Timeout [min]
0 to 999
minutes
Period of inactivity after which a console will be automatically
disconnected from its current CPU Device (default: 0 minutes)
Keyboard Connect
Activated
Activate request of K/M control by keyboard event (key will be
lost)
Deactivated
Function not active (default)
Mouse Connect
Activated
Activate request of K/M control by mouse event
Deactivated
Function not active (default)
Release Time [sec]
0 to 999
seconds
Period of inactivity of a connected CON Device after which K/M
control can be requested by other CON Devices connected to
the CPU Device.
Note:
Set "0" for an immediate transfer in real-time.
Only one CON Device can have keyboard and mouse control at
a time. The other consoles that are connected to the same CPU
Device have a Video Only status (default: 10 sec.)
Macro Single Step
Activated
Execute macro commands sequentially
Deactivated
Function not active (default)