Configuration via Management Software
Draco tera flex
148
To configure shared operation, proceed as follows:
1. Select
System Settings > Switch
in the task area.
2. Click the
Activate Edit Mode
menu item in the toolbar.
3. Activate the
Enable Video Sharing
function.
4. Activate the
Force Connect
function.
5. Activate the
Keyboard Connect
function if taking over control by a keyboard event is to be permitted.
6. Activate the
Mouse Connect
function if taking over control by a keyboard movement should be
possible.
7. Define a
Release Time
of inactivity (0 to 999 seconds) after which control can be taken over.
8. Click the
Apply
button to confirm the changes.
9. Click the
Deactivate Edit Mode
menu item in the toolbar.
Keyboard Connect
and / or
Mouse Connect
are only effective if
Force Connect
and / or
CPU Auto
Connect
are activated.
If the
Keyboard Connect
and / or
Mouse Connect
options are enabled, the
Keyboard Connect
and/or
Mouse Connect
will not take effect until the time interval entered in the