![Ihse Draco tera flex Cat X 1G K480-C16 User Manual Download Page 283](http://html1.mh-extra.com/html/ihse/draco-tera-flex-cat-x-1g-k480-c16/draco-tera-flex-cat-x-1g-k480-c16_user-manual_4052847283.webp)
Draco tera flex
Operation
283
9.6.4
Extender Firmware Status
The firmware status of the extender modules with its name, type, and version is displayed in this menu.
Select
Status & Updates > Status - Extender Firmware
in the task area to query the current firmware
status of the extender modules.
Fig. 216
Management software menu Status & Updates - Status Extender Firmware - Firmware
The following information is displayed in the working area:
Column
Description
ID
Numerical value of the extender module ID
Name
Name of the EXT Unit and the extender module firmware
Port
Port number of the matrix, the extender module is physically connected
Type
Type of the CON / CPU Unit and firmware
Device
Name of the CON Device / CPU Device the EXT Unit is assigned to
Version
Installed firmware version
Firmware types to be updated or firmware conflicts are highlighted in color:
Extender firmware version conflict
Manual update of EXTMSD / EXTIMSD recommended*
Wrong module (CPU/CON mismatch)
Undefined type
* Updating of EXT*MSD is only required, if explicitly stated within the release notes or advised by the
manufacturer’s technical support. EXT*MSD requires manual update via the Mini-USB service port at the