Configuration via Management Software
Draco tera flex
196
To load a EDID template (file extension
.bin
) for a further distribution, proceed as follows:
1. Select
Extender & Devices > EXT Units
in the task area.
2. Click the
Activate Edit Mode
menu item in the toolbar.
3. Click the
EDID
tab on the right side of the working area.
4. Select the EXT Unit of a CPU extender module to transmit the EDID to.
5. Click the
Open
button in the symbol bar of the tab.
6. Navigate to the respective template with the file extension
.bin
and click the
Select
button.
7. Click the
Transmit
button in the symbol bar of the tab.
A query for transmission appears.
8. Click the
Yes
button to transmit the loaded EDID to the CPU extender module.
The progress of the parameter transmission is displayed.
9. Click the
Close
button when the EDID transmission is completed (green).
Fig. 147
Management software menu Extender & Devices - EXT Units - Transmission finished
10. Click the
Deactivate Edit Mode
menu item in the toolbar.
Further options:
•
To locally store existing EDID of a CPU extender module whose EXT Unit is selected, click the
Save
As…
button.
•
To set existing the EDID of a CPU extender module whose EXT Unit is selected back to factory settings,
click the
Reset
button.