![background image](http://html1.mh-extra.com/html/ifm/o3m-zz1103/o3m-zz1103_instructions-for-setup_3920741031.webp)
31
O3M area surveillance
UK
10 Set-up
Before set-up, the area surveillance is set (→ "10.1.3 Configuration wizard").
The following parameters of the 3D sensor and the vehicle are necessary for set-up:
●
inclination angle of the 3D sensor
● height of the 3D sensor (→ "7.3 Measuring the inclination angle and height of the 3D sensor")
●
width of the vehicle incl� tolerance
When the set-up has been completed, the monitoring mode is activated and the system is ready for
operation (→ "10.2 Monitoring mode").
After set-up, carry out a function test:
►
Drive towards an object at typical speed and check the reaction of the system�
10.1 Setting the area surveillance
The area surveillance is divided into 3 zones� The 3 zones represent risk levels, with zone [
] representing the lowest risk level and zone [ ] the highest risk level� The size of the zones can be
adjusted for different vehicles and scenarios� The distance to the detected object determines the active
zone:
●
zone [
] (yellow): risk level 1
●
zone [
] (orange): risk level 2
●
zone [
] (red): risk level 3
If an object is detected in a zone, this causes a change to:
●
the output of the BasicController,
●
the background and text colour of the BasicDisplay,
● the acoustic signal emitted (if a buzzer is connected).
If an object is in more than 1 zone, the closest risk level is displayed�
Readjusting the 3 zones:
► Press the 4 function keys simultaneously (→ "9 Operating and display elements").
In the following, the area surveillance is set via the BasicDisplay� Once the setting has been carried out,
the monitoring mode is activated and the system is ready for operation (→ "10.2 Monitoring mode").
Use the following key combination to switch back to the operating status from any menu:
► Press the 4 function keys simultaneously (→ "9 Operating and display elements").