![background image](http://html1.mh-extra.com/html/ifm/o3m-zz1103/o3m-zz1103_instructions-for-setup_3920741026.webp)
O3M area surveillance
26
The outputs of the BasicController (blocks D, E and F) can be used as input signals for engine
controllers or similar� Block F is reserved�
8.4 Wiring E2M monitor
1
2
①
Power supply
7 wires, open ends
red
U+ (12...32 V DC)
white GND
CAUTION
Malfunction
The wires that are not needed may cause the
E2M monitor to malfunction�
Only the red (U+) and white (GND) wires are
required�
►
Insulate the blue, brown, white/yellow, grey
and yellow wires�
Older versions of the device have a voltage range of
18...30 V DC (revision no. AA).
Current devices have a voltage range of 12���32 V DC
(revision no. AB).
►
Observe the voltage range on the type label�
> The type label indicates the voltage range of the
device�
②
Analogue video input
M16 socket, 4 poles
2
1
3
4
1
Coax cable core (video signal)
2
Coax screen (video GND)
3
U+ (12 V DC)
4 GND
Fig� 18: Wiring E2M monitor
8.5 Connecting the BasicController to the BasicDisplay
①
1� Connect the E3M171 CAN adapter
cable to
①
"P/N1".