![background image](http://html1.mh-extra.com/html/ifm/o3m-zz1103/o3m-zz1103_instructions-for-setup_3920741047.webp)
47
O3M area surveillance
UK
The BasicController signals a critical error (→ "11.4 Error codes 3D
►
Disconnect and reconnect the BasicController's connections to the
devices�
►
Restart the BasicController and the devices�
11.4 Error codes 3D sensor
The following error codes are used by the 3D sensor:
Error code
Description
80
O3M function limited (unavailable)
Interference detected
81
O3M function limited (unavailable)
Spray detected
82
O3M function limited (unavailable)
Missing movement data from the vehicle
83
O3M function limited (unavailable)
Invalid alignment of the 3D sensor
84
O3M function limited (unavailable)
No error-free signal transmission between sensor
and illumination unit�
85
O3M function limited (unavailable)
Internal fault
86
O3M function limited (unavailable)
Blockage detected
94
O3M function limited (unavailable)
Availability != 0
►
Contact ifm support
95
O3M function limited (unavailable)
The O3M is not available, availability = 255
►
Contact ifm support
96
O3M function limited (unavailable)
Returning to standard Run mode from limited Run
mode
97��110
O3M function limited (unavailable)
Limited Run mode due to active DTC, DTC will be
indicated� Error code range reserved�
111
O3M function limited (unavailable)
Limited run mode due to active DTC, DTC not
classified�
►
Contact ifm support
113
O3M incompatible
The CAN interface specification is inconsistent� The
O3M has an incorrect firmware version�
114
O3M incompatible
The application configuration of the O3M is not
compatible�
►
Flash a suitable O3M application configuration�
115
O3M incompatible
The user configuration requires a specific CAN
interface specification which does not correspond to
the one of the current O3M�
►
Flash an O3M firmware with suitable CAN
interface specification or discard the current user
configuration�
116
O3M incompatible
The user configuration requires a specific O3M
application configuration which does not correspond
to the one of the current O3M�
►
Flash a suitable O3M application configuration or
discard the current user configuration�
127
O3M incompatible
The O3M device information cannot be read or
transmitted�
224��239
O3M ERROR
Emergency mode with known error cause, DTC will
be indicated� Error code range reserved�