45
O3M area surveillance
UK
11.2 Operating states
The system status shows the operating states of the BasicDisplay, BasicController and 3D sensor (→
Fig� 21: Indication of the operating states
The following operating states are indicated:
Display
Operating status
NORMAL
The device is connected and compatible�
STARTUP
The device starts�
STANDBY The device is in standby�
PAIRING
The 3D sensor is synchronised with an illumination unit�
CALIB
The 3D sensor is automatically calibrated�
N/A
The device is not connected
LIMITED
The device has limited functionality�
Code 97
INCOMPAT
The device has an incompatible configuration and must be reflashed (→ "11.4 Error
Code 114
INCOMPAT
The device is incompatible and must be reflashed (→ "11.4 Error codes 3D sensor").
Code 127
TIMEOUT
The device is disconnected due to a timeout�
Code 254
ERROR
The device is in error mode due to an unknown error�
Code 240
11.3 Status indications in monitoring mode
The following status indications are shown on the BasicDisplay in monitoring mode:
The set values are transferred to the 3D sensor�
The 3D sensor is not available during this restart�
The sensor is started again�
The 3D sensor is not available during this restart�