8.3 Wiring BasicController
The supply cables, CAN interfaces and input/outputs are connected via 6�3 x 0�8 mm blade male terminals on
the front of the BasicController�
The BasicController contains an application-specific configuration (the area surveillance application
package). Depending on the configuration, only certain inputs are available.
A
B
C
D
E
F
N2
P/N1
①
Inputs
②
Outputs
③
Supply and CAN interfaces
Fig� 17: Wiring BasicController
Block Connection Description
Number
of poles
A
Inputs
IN0���3
Reserved� Do not use�
8
B
IN4���7
Reserved� Do not use�
C
IN8���10
Reserved� Do not use�
IN11
High: system in standby, low: system active
The behaviour of the input is adjustable (→ "10.1.2
D
Outputs
OUT0 binary
High: system available, low: system not available
OUT1 binary
High: object in red zone
OUT2 binary
High: object in orange zone
OUT3 binary
High: object in yellow zone
E
OUT4 binary
High: object in red, orange or yellow zone
OUT5 binary
-
OUT6 binary
OUT7 binary
Connection for optical signal transmitter:
●
permanently on: red zone
●
flashing frequency high: orange zone
●
flashing frequency low: yellow zone
F
OUT8,
analogue
0-100: The distance to the next object is indicated in
%� 100% corresponds to 10 m
OUT9, binary
Buzzer:
●
continuous tone: red zone
●
tone frequency high: orange zone
●
tone frequency low: yellow zone
The volume can be adjusted (→ "10.1.2 Expert
OUT10, binary High: sensor pane dirty, low: sensor pane clean
OUT11, binary High: normal operating mode, low: error state
P/N1 CAN interface 1 and supply
6
N2
CAN interface 2
4