PRS-330 Series
ETHERNET INTERFACE OPTION
31
The Digital I/O con
fi
guration values are not
affected by the LAN Reset operation.
Command
Function
Factory Setting
IP Mode
Static or DHCP
Mode
Static
IP Address
0.0.0.0 to
255.255.255.255.0
192.168.0.2
Net Mask
0.0.0.0 to
255.255.255.255.0
255.255.255.0
COMM Timeout
Sets socket timeout
120 sec.
Auto Disconnect
Aborts socket if link
count goes to 0
Off
Table 4-2 Default Settings
5.8 PRS Programming
A PRS SCPI command reference is in-
cluded in Appendix A. This gives a complete
set of commands.
An example of commands to be sent to
place the PRS in remote, this must be done
fi
rst otherwise the will be no remote control of
output impedance, and then con
fi
gure the unit
for a speci
fi
c impedance value.
Where the command string is constructed
as described in Appendix A and Appendix B.
A command string might be, for example:
SOURce:DATA 1000000.1