PRS-330 Series
ETHERNET INTERFACE OPTION
29
1. Connect the board directly to the WIN32 PC
that will be running the Con
fi
guration Utility.
Disconnect the PC from the company network
and use the supplied Ethernet Crossover Cable to
connect the PC to the board as shown in Figure
4-6. This will eliminate any potential network
con
fl
icts while con
fi
guring the board.
g
g
Figure 4-6 9006 Connected to PC with a
Crossover Cable
Alternately, use a standard Ethernet patch cable
to connect the 9006 to the same hub or switch
that the PC running the Con
fi
guration Utility is
connected to as shown in Figure 4-7. Temporarily
disconnect the local network connection to avoid
network con
fl
icts until the board is con
fi
gured.
Figure 4-7 9006 Connected to the local hub
2. Apply power to the board
3. Check your PC’s network settings to be sure
its IP address is in the 192.168.1.xxx range so
it can communicate with the board’s default IP
address. To check, right-click on My Network
Places and click on Properties. Right-click on
Local Area Connection and click Properties.
Highlight Internet Protocol (TCP/IP) and click
Properties. If your PC’s IP address is in a different
range, record the current settings and temporarily
set the following network values:
Check ‘Use the following IP Address’
IP Address 192.168.1.254
Subnet mask 255.255.255.0
4. Run the VXI11_config program. The
Con
fi
guration Utility opens a window as shown
in Figure 4-8. Initially only the Find Server, Help
and Exit keys are enabled on the program
window. The other keys will be enabled as you
advance through the program.
5. Click on the Find Server key. The program
scans for all VXI-11 Services connected to the
local LAN or to your PC. (The 9006 is an RPC
server which provide a VXI-11 Service) The
results are displayed in the Results box.
6. When the servers(s) have been found, use the
pulldown arrow in the Found Servers box to view
the Found Server addresses. The board’s
default address is 192.168.1.254. Highlight the
board’s IP address and click the Create Link key.
If the server is not found, you can enter the default
IP address (192.168.1.254) in the Found Servers
box. Click the Create Link key.
Summary of Contents for PRS-330 series
Page 2: ...TEL 516 334 5959 800 899 8438 FAX 516 334 5988 www ietlabs com IET LABS INC...
Page 12: ...PRS 330 Series v Table of Contents Page left intensionally blank...
Page 18: ...SPECIFICATIONS PRS 330 Series 6 Page left intensionally blank...
Page 34: ...OPERATION PRS 330 Series 22 Page left intensionally blank...
Page 36: ...USB INTERFACE PRS 330 Series 24 Page left intensionally blank...
Page 44: ...PRS 330 Series ETHERNET INTERFACE OPTION 32...
Page 48: ...PROGRAMMING PRS 330 Series 36 Page left intensionally blank...
Page 67: ...PRS 330 Series APPENDIX B 55...