IDT Non-Transparent Mode Operation
PES16NT2 User Manual
10 - 139
April 15, 2008
Notes
2
INMSG2
RW1C
0x0
Inbound Message 2.
This bit is set whenever a value is
written to the OUTMSG2 register located in PCI configura-
tion space on the opposite side of the non-transparent
bridge. The action taken when this bit is set is determined
by the Interrupt Control 0 (INTCTL0) register.
3
INMSG3
RW1C
0x0
Inbound Message 3.
This bit is set whenever a value is
written to the OUTMSG3 register located in PCI configura-
tion space on the opposite side of the non-transparent
bridge. The action taken when this bit is set is determined
by the Interrupt Control 0 (INTCTL0) register.
4
INDBELL
RO
0x0
Inbound Doorbell.
This bit is set whenever a bit is set in
the Inbound Doorbell (INDBELL) register. The action taken
when this bit is set is determined by the Interrupt Control 0
(INTCTL0) register.
5
OSRD
RW1C
depends
on reset
condition
Sticky
Opposite Side Reset Detected.
This bit is set whenever a
fundamental or hot reset is detected on the opposite side of
the non-transparent bridge. The action taken when this bit
is set is determined by the Interrupt Control 0 (INTCTL0)
register.
6
OSPSTATEM
RW1C
0x0
Opposite Side Power State Modification.
This bit is set
whenever a modification is made to the PSTATE field in
the PMCSR register on the opposite side of the non-trans-
parent bridge.
7
PALINKUP
RW1C
Undefined
Sticky
Port A Link Up.
This bit is set whenever the port A data
link layer transitions from a DL_Down to a DL_Up state.
The action taken when this bit is set is determined by the
Interrupt Control 1 (INTCTL1) register.
8
PALINKDN
RW1C
Undefined
Sticky
Port A Link Down.
This bit is set whenever the port A data
link layer transitions from a DL_up to a DL_Down state.
The action taken when this bit is set is determined by the
Interrupt Control 1 (INTCTL1) register.
10:9
Reserved
RO
0x0
Reserved field.
11
PCLINKUP
RW1C
Undefined
Sticky
Port C Link Up.
This bit is set whenever the port C data
link layer transitions from a DL_Down to a DL_Up state.
The action taken when this bit is set is determined by the
Interrupt Control 1 (INTCTL1) register.
12
PCLINKDN
RW1C
Undefined
Sticky
Port C Link Down.
This bit is set whenever the port C data
link layer transitions from a DL_up to a DL_Down state.
The action taken when this bit is set is determined by the
Interrupt Control 1 (INTCTL1) register.
31:13
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
Summary of Contents for 89HPES16NT2
Page 14: ...DT List of Figures PES16NT2 User Manual viii April 15 2008 Notes...
Page 20: ...IDT Register List PES16NT2 User Manual xiv April 15 2008 Notes...
Page 32: ...IDT PES16NT2 Device Overview PES16NT2 User Manual 1 12 April 15 2008 Notes...
Page 50: ...IDT Link Operation PES16NT2 User Manual 3 6 April 15 2008 Notes...
Page 62: ...IDT Power Management PES16NT2 User Manual 5 4 April 15 2008 Notes...
Page 78: ...IDT SMBus Interfaces PES16NT2 User Manual 6 16 April 15 2008 Notes...
Page 83: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 5 April 15 2008 Notes...
Page 84: ...IDT NTB Upstream Port Failover PES16NT2 User Manual 7 6 April 15 2008 Notes...
Page 130: ...IDT Transparent Mode Operation PES16NT2 User Manual 9 44 April 15 2008 Notes...
Page 284: ...IDT Non Transparent Mode Operation PES16NT2 User Manual 10 154 April 15 2008 Notes...