Note: To add a second reader to the same door follow the same wiring as Reader 1, except Reader 2s
white wire goes to R2 and yellow wire goes to Yel 2.
Integrated Reader
The Integrated Reader is wired directly into the X-Series Keypad Bus.
To default the Integrated Reader you must short the Exit Button wires together for 3 seconds on power up.
NB: You cannot power a magnetic lock with the aXess interface or Integrated Reader. Use a Smart PSU to
power the magnetic lock, or use a Smart PSU and Bus Isolator to power the aXess Interface and magnetic
lock.
The X-Series Keypad Bus to the aXess Interface RS485 Bus:
D+ to 485+
D - to 485 -
Red – 12v power
Black – 0v power
White – Keypad Bus D-
Yellow – Keypad Bus D+
Orange – Normally Closed Output
Brown – Door Switch
Blue – Normally Closed Output
White – Exit Button
White – Exit Button
Purple – Door Switch