IDS X-Series Training v2.7 | Event Reporting
71
Location 575 Global Split Reporting
Location Type: Bitmap
LED On/Off
Action
Explanation
Split
Reporting
Option
Default
1
OFF
IDSwift Download
Accessed
This option reports when the system has been
communicated with by the download software.
9
OFF
2
OFF
AC Fail on Smart
Power Supply
This option reports when the Smart Power
Supply has an AC failure.
10
OFF
3
OFF
AC Restore on
Smart Power
Supply
This option reports when the Smart Power
Supply has an AC restore.
11
OFF
4
OFF
Low Battery on
Smart Power
Supply
This option reports when the Smart Power
Supply has a low battery.
12
OFF
5
OFF
Battery Restore
on Smart Power
Supply
This option reports when the Smart Power
Supply has a battery restore.
13
OFF
6
OFF
Fuse Fail on
Smart Power
Supply
This option reports when the Smart Power
Supply has a fuse failure.
14
OFF
7
OFF
Fuse Restore on
Smart Power
Supply
This option reports when the Smart Power
Supply has a fuse restore.
15
OFF
Location 581 - 588 Partition Split Reporting
Location Type: Bitmap
LED On/Off
Action
Explanation
Split
Reporting
Option
Default
1
ON
Duress Reporting
When a duress code is used this
enables the contact ID code to be sent
to the security company.
9
OFF
2
ON
Keypad Panic Reporting
When the “P” key on the keypad is
pressed a panic signal is sent to the
security company.
10
OFF
3
ON
Fire Reporting
When the “F” key is pressed or a zone is
a fire zone and is violated a fire signal is
sent to the security company.
11
OFF
4
ON
Medical Reporting
When the “M” key is pressed or the
option “Medical alarm if no movement is
detected” is programmed a medical
signal will be sent if this option is
enabled.
12
OFF
5
ON
Keypad Lockout
Reporting
If this option is enabled in location 221 –
228 and an incorrect code is entered the
number of times set in location 20 within
the time set in location 21, the signal will
be sent.
13
OFF
6
Reserved
7
Off
Arm without User Code
Reporting
When arming with the “Quick Arm” keys
or an arm/disarm zone this option must
be enabled to send an arm signal.
15
OFF
8
Reserved