88
IDS X-Series Training v2.7
Stay Arm Profiles Example
During the early evening a family may access all the rooms in the house, but want all external zones armed.
When they go to bed all rooms except the bedrooms must be armed.
This family could have 2 profiles, one profile for early evening and another for bed time.
Only one profile is active, the others
need to be activated by entering the profile and adding stay zones.
How to enable stay arm profiles:
Explanation
Key Presses
Press and hold the [5] stay arm key and then press the profile number
1 to 4 and release
[5] then
[1] or [2] or [3] or [4]
Press and hold the [3] stay key until the beep
[3] Stay
Enter each zone to be bypassed until complete, then press the [#]
key to exit
[5] [*] [7] [*] [8] [*] [2] [1] [*].....[#]
To access the next 16 zones press the [*] key, add the zones as
needed
[*]
Now zone 17 is represented by zone 1, 18 by 2, 19 by zone 3, etc.
[1] [*] [8] [*] [1] [0] [*] [1] [5][*]
When complete press the [#] key
[#]
Toggling between the stay profiles, can be done in three ways:
1.
Toggle method (Note: only if there is more than one profile with stay zones)
a.
Press and hold the [5] key until the system arms. (The system will arm in the profile that it
last armed in.)
b.
Press and hold the [5] key again until the beep. The zones will change.
NOTE:
By pressing the [5] key in this manner will toggle through all active profiles
c.
Press and hold the [MODE] key until the beep, then press the [2] key followed by the [*] key
and finally the [STAY PROFILE NUMBER] followed by the [*] key.
2.
Selection method
a.
Press and hold the [5] key, then press the profile number and release
b.
Now press and hold the [5] key until armed
3.
Stay Profile Menu
a.
Press the [5] key, then the keypad will ask you in which stay profile to arm. This feature only
works with an LCD keypad.
Note: This option must be enabled under installer settings, location 251 – 258: Keypad Options
1 to 16
17 to 32
33 to 48
49 to 64
Zones
Curve Keypad
Classic Keypad