IDS X-Series Training v2.7 | Partition Options
47
Locations 221 to 228: Extra Partition Options
Location Type: Bitmap
These are more partition options that can be set.
LED Default
Action
Description
1
OFF
Automatic Re-enabling of Shutdown
Zones at the Time of the Dialler Test
If a zone is disabled due to reaching the number of triggers in
location 10 when armed, the alarm will try and re-enable those
zones at auto test.
2
OFF
Bypassing of Common Zones
If zones are in more than one partition and the zones may
need to be bypassed at some time this option must be
enabled in all partitions it belongs to.
3
OFF
Delay Before Communications
This option will delay any communication for the time set in
location 45. Except for panic or duress signals.
4
OFF
Keypad Lockout
If a person enters a wrong code the number of times set in
location 20 the keypad will stop responding to any key
presses, for the amount of time set in location 21.
5
OFF
Disable Silent Keypad Panic
This will stop the siren from sounding if the P key on the
keypad is pressed and a panic is triggered.
6
OFF
Toot on Successful Communication
When closing reporting is enabled and this option is on the
siren will only toot once the system is armed and has
communicated that to the security company successfully.
7
OFF
4x2 Stay Zone Reporting
When enabled and stay closing is enabled all bypassed
zones will be reported to the security company when using
4x2 reporting.
8
OFF
Zone Restoral Sends After Siren
Time Out
When enabled a zone restoral will only be sent once the siren
time out period has completed.
Location 230: Exit Delay
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This is the time the partition waits before fully arming. During this time any zones that are entry/exit or follower
zones are disabled and only when the exit delay is finished do these zones become active. By default the
exit delay is indicated by the keypad beeping.
Format: mmss
Default: 0030
Valid range: 0000 to 5959
Exercise:
Instructions
Keypad presses
Enter the location 230
[2][3][0] [*]
Enter partition 1’s sub-location
[1] [*]
Change the 30 sec default to 10sec (mmss)
[0][0] [1][0] [*]
Exit the location
[#]