IDS X-Series Training v2.7 | Locations
27
Zone Programming Example
Exercise:
1.
Programming zones using both the string and bitmapped methods.
a.
Let’s program zones 9 to 16 using the string method and zones 17 to 24 using the sub-location
method
b.
The table describes what type of zone each one will be
Zone
Type
Value
Zone
Type
Value
9
Secondary Entry / Exit
08
17
Entry / Exit
01
10
Follower
02
18
Follower
02
11
Follower
02
19
Instant
04
12
Instant
04
20
Instant
04
13
Instant
04
21
Follower
02
14
Outdoor Instant
15
22
Follower
02
15
Outdoor Instant
15
23
Outdoor Instant
15
16
Panic
03
24
Panic
03
c.
To program zones 9 to 16 into the system via the string method:
Instructions
Key presses
Enter installer mode
[#] [9] [9] [9] [9] [*]
Enter the location 2
[2] [*]
Type in the complete string of information for all
zones
[0][1] [0][2] [0][4] [0][4] [0][4] [1][5] [1][5] [0][5] [*]
d.
Programming zones 17 to 24 using the sub-location method:
Instructions
Key presses
Enter location 3
[3] [*]
Press the [*] key to sub-location method
[*]
Enter the value for an entry/exit zone followed by the [*] key.
[0] [1] [*]
Press the [*] key to go to the next sub-location - Zone 18
[*]
Follower zone
[0] [2] [*]
Next Sub-location - Zone 19
[*]
Instant zone
[0] [4] [*]
Next Sub-location - Zone 20
[*]
Instant zone
[0] [4] [*]
Next Sub-location - Zone 21
[*]
Follower zone
[0] [2] [*]
Next Sub-location - Zone 22
[*]
Follower zone
[0] [2] [*]
Next Sub-location - Zone 23
[*]
Outdoor instant zone
[1] [5] [*]
Next Sub-location - Zone 24
[*]
Panic zone
[1] [5] [*]
To exit location 3 press the [#] key
[#]
Note: You will still be installer mode
e.
Programming zones 7 and 8 using the sub-location method from Root location 1
Instructions
Key presses
Enter location 1
[1] [*]
Enter the sub-location number for zone 7 and press the
[*]
key
[7] [*]
Enter the value for an instant zone followed by the
[*]
key.)
[0] [4] [*]
Now zone 8
[8] [*]
Panic zone
[0] [3] [*]
To exit location 1 press the
[#]
key
[#]
Note: You will still be installer mode