Globally Triggered Outputs
Location Type: Extended
These events do not depend on a partition but are system related events. Each event can be programmed
to activate a PGM output.
Loc
Sub-
loc
Event
Description
Default
423 1
AC Fail Programmable
Output
By default the system monitors the 16V AC and will trigger these
outputs if there are any changes.
0000
2
AC Restore Programmable
Output
0000
3
Low Battery Programmable
Output
The battery is monitored constantly and will trigger these outputs if
the battery’s power becomes too low, or is restored.
0000
4
Low Battery Restore
Programmable Output
0000
5
Auto Test Programmable
Output
The system can be set to do a test at different intervals as
programmed into location 32.
0000
6
Download Programmable
Output
When someone has connected to the alarm via the download
software.
0000
7
Siren Tamper
Programmable Output
If siren monitoring is enabled and the siren goes missing.
0000
8
Aux 12V Trouble
Programmable Output
The 12V output on the panel is monitored constantly.
0000
Loc
Sub-
loc
Event
Description
Default
424 1 Reserved
2
Bus-wired Peripheral
Tamper Programmable
Output
This is a tamper on any device that connects to the system via the
communication bus.
0000
3
Bus-wired Peripheral Fail
Programmable Output
If the actual communication bus fails.
0000
4
Box Tamper
Programmable Output
The alarm panel has a 2 pin connector that can be connected to a
switch to monitor the door of the panel box.
0000
5
Dedicated Panic
Programmable Output
Onboard dedicated panic connector is next to Zone 8.
0102
6
Communication Fail
Programmable Output
If the system cannot communicate and deliver an event via phone
after the number of tries programmed into location 47.
0000
7
Telephone Line Tamper
Programmable Output
The telephone line voltage is monitored and if this changes then the
output will trigger.
0000
8 Telephone Line Restore
Programmable Output
Set this to restore the output of option 7 if it was set to latch.
0000
Loc
Sub-
loc
Event
Description
Default
425 1 RF Jam
If a signal is detected that interferes with the receiver a jam will be
logged and an output can be triggered and reset when the jamming
signal stops.
0000
2 RF Jam Reset
0000
3 RF Supervision Fail
Each device is set to send a signal, either every 90min or 12 hours
to confirm it is still available. If the system does not receive the
signals a supervision fail is logged.
0000
4 RF Detector Battery Low
When the wireless device detects that its battery voltage is low it will
inform the system and the system can set the output to warn the
occupants and restores when battery is replaced.
0000
5
RF Detector Battery
Restore
0000
6 RF Receiver Battery
If the receiver’s battery goes low an output can be triggered and
reset when restored.
0000
7 RF Receiver Battery restore
0000