- 36 -
A26
Main EEV hot water initial opening 00 0~480
350 T≥25
℃
A27
Main EEV hot water initial opening 01 0~480
300[10
,
25)
A28
Main EEV hot water initial opening 02 0~480
250[-10
,
10)
A29
Main EEV hot water initial opening 03 0~480
200 T
<
-10
℃
A30
Main EEV heating automatic
adjustment lower limit 00
0~480
80 ambient tempT≥14
℃
A31
Main EEV heating automatic
adjustment lower limit 01
0~480
80[9
,
14)
A32
Main EEV heating automatic
adjustment lower limit 02
0~480
80[4
,
9)
A33
Main EEV heating automatic
adjustment lower limit 03
0~480
80[-5
,
4)
A34
Main EEV heating automatic
adjustment lower limit 04
0~480
80[-10
,
-5)
A35
Main EEV heating automatic
adjustment lower limit 05
0~480
80[-16
,
-10)
A36
Main EEV heating automatic
adjustment lower limit 06
0~480
80[-23
,
-16)
A37
Main EEV heating automatic
adjustment lower limit 07
0~480
80 T
<
-23
℃
A38
Main EEV exhaust temp adjustment
70
℃
~125
℃
95
℃
A39
Main EEV opening under defrost
20~450
450
A40
Main EEV minimum opening under
Hot water mode
50~150
60
A41
Main EEV mode selection
0-automatic /
1-manual
0
A42
Main EEV manual steps
20~450
350
A43
Main EEV superheat proportional
coefficient
1~6
5
A44
Main EEV superheat differential
coefficient
1~180
1
A45
EEV initial adjustment mode
0 fixed/
1adjustable
1
B01
Auxiliary EEV mode selection
0-auotomatic
/1-manual
0