16
Low DC bus voltage
Input voltage is too low, PFC module
fault
Check the input voltage,
replace the module
32
High DC bus voltage
Input voltage is too high, PFC module
fault
Replace the inverter module
64
Heat sink temp is too
high
Fan motor fault, blocked air duct
Check the fan motor and air
duct
128
Heat sink sensor fault
Heat sink sensor short circuit or open
circuit fault
Replace inverter module
257
Communication fault
and heat sink temp is
too high
The inverter module did not receive the
command from main board
Check the communication
wire
between
inverter
module and main board
258
Power input lack phase Input lack phase
(
it is valid for three
phase
)
Check the input cable
260
Power input over current Input three-phase unbalanced (it is
valid for three-phase module )
Check the input three phase
voltage
264
Power input voltage is
too low
Input voltage is too low
Check the input voltage
272
High pressure fault
Compressor
high
pressure
fault(standby)
288
IPM temp is too high
Fan motor fault, blocked air duct
Check the fan motor and air
duct
320
compressor
peak
current is too high
The line current of the compressor is
too large, and the driver does not match
the compressor
Replace the inverter module
384
PFC module temp is too
high
PFC module temp is too high
Check the PFC module
5.5. WIFI CONTROL FUNCTION
WIFI settings
P
ress the
key +
key at the same time for 3 seconds to enter the "default mode" network configuration,
the "
" icon flashes quickly when entering;
At the same time, press the
the
key for 3 seconds to enter the "compatibility mode" network
configuration, the "
" icon flashes slowly when entering;
1. Software download and installation:
Enter " Multi-Machine" in Google Play and App Store, search for Multi-Machine APP, download and install;
Summary of Contents for ISW-10 SF1-DN1
Page 21: ... 21 XD 05BSPM ...
Page 56: ... 56 By sliding the button you can adjust the setting parameters Function buttons ...
Page 65: ......