- 38 -
B22
Auxiliary EEV heating initial opening
03
0~480
50[-5
,
4)
B23
Auxiliary EEV heating initial opening
04
0~480
50[-10
,
-5)
B24
Auxiliary EEV heating initial opening
05
0~480
50[-16
,
-10)
B25
Auxiliary EEV heating initial opening
06
0~480
60[-23
,
-16)
B26
Auxiliary EEV heating initial opening
07
0~480
60 T
<
-23
℃
B27
Auxiliary EEV hot water initial opening
00
0~480
0
T≥25
℃
B28
Auxiliary EEV hot water initial opening
01
0~480
0
[10
,
25)
B29
Auxiliary EEV hot water initial opening
02
0~480
50
[-10
,
10)
B30
Auxiliary EEV hot water initial opening
03
0~480
30
T
<
-10
℃
B31
Auxiliary EEV heating automatic
adjustment lower limit 00
0~480
30
Ambient
Temp.T≥14
℃
B32
Auxiliary EEV heating automatic
adjustment lower limit 01
0~480
30 [9
,
14)
B33
Auxiliary EEV heating automatic
adjustment lower limit 02
0~480
30 [4
,
9)
B34
Auxiliary EEV heating automatic
adjustment lower limit 03
0~480
30 [-5
,
4)
B35
Auxiliary EEV heating automatic
adjustment lower limit 04
0~480
30 [-10
,
-5)
B36
Auxiliary EEV heating automatic
adjustment lower limit 05
0~480
30 [-16
,
-10)
B37
Auxiliary EEV heating automatic
adjustment lower limit 06
0~480
30 [-23
,
-16)
B38
Auxiliary EEV heating automatic
adjustment lower limit 07
0~480
30 T
<
-23
℃