Chapter 5 function code
table
- 82
-
Parameter
Parameter bit selection Delay control parameter Parameter bit selection
P43.02
P43.03
=
x
P43.04,P43.05
P43.01
Delay Unit 1
Parameter input
Obtain delay unit
Turn
Logical
output
Ref
status parameter
on/turn off
choice 0-
positive
(00.00
~
98.00)
input Ref bit x
delay
logic 1-
control
inverse
logic
delay unit 1 block diagram
The picture shows the delay unit 1 block diagram, delay unit 2 to 6 and so on. Delay unitss can be combined with
comparator units and logic units for more complex applications.
P43.01
Delay unit 1-6
logicl
000000B-111111B
0
☆
P43.02
Delay unit 1
input parameter
selection
00.00-98.99(function code index)
0000
☆
P43.03
Delay unit 1
input bit
selection
0-15
0000
☆
P43.04
Delayunit 1 on
delay time
0.0s
~
3000.0s
0000
☆
P43.05
Delayunit 1 off
delay time
0.0s
~
3000.0s
0000
☆
P43.06
Delay unit 2
input parameter
selection
00.00-98.99(function code index)
0000
☆
P43.07
Delay unit 2
input bit
selection
0-15
0000
☆
P43.08
Delay relay 2 on
delay time
0.0s
~
3000.0s
0.0s
☆
P43.09
Delayunit2 off
delay time
0.0s
~
3000.0s
0.0s
☆
P43.10
Delay unit 3
input parameter
selection
00.00-98.99(function code index)
0.0s
☆
P43.11
Delay unit 3
input bit
selection
0-15
0.0s
☆
P43.12
Delay unit3 on
delay time
0.0s
~
3000.0s
0.0s
☆
P43.13
Delay unit3 off
0.0s
~
3000.0s
0.0s
☆