Chapter3 product appearance and wiring
ICON500
high performance vector control frequency inverter user
manual
- 10
-
Table 3-1 ICON500 series appearance and installation dimension
SIZE
Appearance and installation dimension
(
mm
)
A
B
H
H1
W
D
Φd
Mounting
screws
SIZE A
87
206.5
215
/
100
170
ø5.0
M4X16
SIZE B
114
239.5
250
/
130
180
ø5.0
M4X16
SIZE C
159
298
310
/
180
193
Ø6.0
M5X20
SIZE D
165
350
365
210
205
Ø6.0
M5X20
SIZE E
170
437
452.5
260
230
Ø7.0
M6X16
SIZE F
250
535
555
310
275
Ø10.0
M8X20
SIZE G
280
620
640
350
290
Ø10.0
M8X20
Removal and installation of cover and inlet plate
SIZEA
~
SIZE CRemoval and installation of cover and inlet plate
:
Removal steps
Step 1: Open the top cover
①
Unscrew the screw on the cover
②
Lift up the cover
③
Remove the cover from the front
Step 2: Take out the inlet board
①
Hold down the sides of the inlet plate with your
thumb and middle finger
②
Press to disengage the buckle and pull it out of
the board
installation