14
2
BIIS 1200 OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
■
Stun function
When the specified ID, set as a killer ID, is received, the stun
function is activated.
When a killer ID is received, the transceiver switches to the
password required condition. Entering the password with the
keypad is necessary to operate the transceiver again in this
case.
■
BIIS indicators
The following indicators are available for the BIIS operation
on an MSK channel.
CONNECT
: Individual/group calls are successful.
OK
: Message (status or SDM) transmission was
successful.
FAILED
: No answer back is received.
WAIT
: Appears during retry of the call (2nd call).
CLR DOWN
: End the call.
BUSY
: The operating channel is busy.
■
Priority A channel selection
When one of the following operations is performed, the trans-
ceiver automatically selects the Priority A channel.
Priority A is selected when:
• A clear down signal is received or transmitted
- Set the ‘Clear down’ option as ‘Enable’ in ‘Move to PrioA
CH.’
• Turning the power ON
Priority A channel is selected each time the transceiver
power is turned ON.
• Status call
Priority A channel is selected when transmitting a status
call.
- Enable the ‘Send Status on PrioA CH’ item in the MSK
configuration.