12-5
12
SCANS
■
Programmed scan
A Programmed scan searches for signals between
Scan Edge memory channels “P1” and “P2.”
Before starting the programmed scan, you must enter
Scan Edge frequencies into these channels.
If the same frequencies are entered into Scan Edge
memory channels P1 and P2, the Programmed
scan does not start.
The Multi-function screens are OFF.
Push [V/M].
q
• Selects the VFO mode.
• Push [V/M] toggles between the VFO and Memory
modes.
Push
w
a Mode key
to select the desired operating
mode.
• The operating mode can be changed while scanning.
e
Push [TS] to select the desired tuning steps.
• The tuning steps can be changed while scanning.
Push [SCAN](F).
r
• The Scan screen is displayed.
Push [PROG](F).
t
• The Programmed scan starts.
•
“
PROGRAM SCAN
”
and decimal points blink while scan-
ning.
• Push [PROG](F) to cancel the scan.
• Rotating [MAIN DIAL] also cancels the scan.
• Hold down [RECALL](F) for 1 second to recall the fre
-
quencies that are set before starting the scan (P1 and
P2), if desired.
When the scan detects a signal, the scan stops,
y
pauses or ignores it, depending on the Scan Re-
sume setting and the squelch status.
[MAIN DIAL]
[TS]
[V/M]
[EXIT/SET]
Mode keys
(F) Function keys
• While scanning
Blinks
Blinks