122
IBM z13s Technical Guide
Table 3-5 shows all LPAR modes, required characterized PUs, operating systems, and the PU
characterizations that can be configured to an LPAR image. The available combinations of
dedicated (DED) and shared (SHR) processors are also shown. For all combinations, an
LPAR also can have reserved processors that are defined, allowing nondisruptive LPAR
upgrades.
Table 3-5 LPAR mode and PU usage
Dynamically adding or deleting a logical partition name
Dynamically adding or deleting an LPAR name is the ability to add or delete LPARs and their
associated I/O resources to or from the configuration without a POR.
The extra channel subsystem and multiple image facility (MIF) image ID pairs (CSSID/MIFID)
can be later assigned to an LPAR for use (or later removed). This process can be done
through dynamic I/O commands by using HCD. At the same time, required channels must be
defined for the new LPAR.
Adding logical processors to a logical partition
Logical processors can be concurrently added to an LPAR by defining them as reserved in
the image profile and later configuring them online to the operating system by using the
appropriate console commands. Logical processors can also be concurrently added to a
logical partition dynamically by using the Support Element “Logical Processor Add” function
under the “CPC Operational Customization” task. This SE function allows the initial and
reserved processor values to be dynamically changed. The operating system must support
LPAR mode
PU type
Operating systems
PUs usage
ESA/390
CPs
z/Architecture operating systems
ESA/390 operating systems
Linux on z Systems
CPs DED or CPs SHR
CPs
and
zIIPs
z/OS
z/VM (V6R2 and later for guest
exploitation)
CPs DED
and
(
or
)
zIIPs DED
or
CPs SHR
and
(or) zIIPs SHR
ESA/390 TPF
CPs
z/TPF
CPs DED or CPs SHR
Coupling
facility
ICFs
or
CPs
CFCC
ICFs DED
or
ICFs SHR,
or
CPs DED
or
CPs SHR
Linux only
IFLs
or
CPs
Linux on z Systems
z/VM
IFLs DED
or
IFLs SHR,
or
CPs DED
or
CPs SHR
z/VM
CPs, IFLs,
zIIPs, or
ICFs
z/VM (V6R2 and later)
All PUs must be SHR or DED
zACI
a
a. z Appliance Container Infrastructure
IFLs,
or CPs
IBM zAware
b
IBM z/VSE Network Appliance
c
b. Encapsulated as a firmware appliance.
c. Planned
IFLs DED
or
IFLs SHR,
or
CPs DED
or
CPs SHR
Partition profile: Cryptographic coprocessors are not tied to partition numbers or MIF IDs.
They are set up with Adjunct Processor (AP) numbers and domain indexes. These are
assigned to a partition profile of a given name. The client assigns these AP numbers and
domains to the partitions and continues to have the responsibility to clear them out when
their profiles change.
Summary of Contents for z13s
Page 2: ......
Page 3: ...International Technical Support Organization IBM z13s Technical Guide June 2016 SG24 8294 00 ...
Page 24: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ...136 IBM z13s Technical Guide ...
Page 226: ...198 IBM z13s Technical Guide ...
Page 256: ...228 IBM z13s Technical Guide ...
Page 414: ...386 IBM z13s Technical Guide ...
Page 464: ...436 IBM z13s Technical Guide ...
Page 476: ...448 IBM z13s Technical Guide ...
Page 498: ...470 IBM z13s Technical Guide ...
Page 502: ...474 IBM z13s Technical Guide ...
Page 568: ...540 IBM z13s Technical Guide ...
Page 578: ...550 IBM z13s Technical Guide ...
Page 584: ...556 IBM z13s Technical Guide ...
Page 585: ...ISBN 0738441678 SG24 8294 00 1 0 spine 0 875 1 498 460 788 pages IBM z13s Technical Guide ...
Page 586: ......
Page 587: ......
Page 588: ...ibm com redbooks Printed in U S A Back cover ISBN 0738441678 SG24 8294 00 ...