Note:
To make sure that there is adequate system cooling, do not operate the
server for more than 2 minutes without either a hard disk drive or a filler panel
installed in each bay.
Installing a hard disk drive
Locate the documentation that comes with the hard disk drive and follow those
instructions in addition to the instructions in this chapter.
Installing a 3.5-inch simple-swap hard disk drive
To install a simple-swap Serial ATA hard disk drive, complete the following steps.
Hard disk drive
assembly
Filler panel
1. Read the safety information that begins on page vii and “Installation guidelines”
2. Make sure that the server cover is in place and fully closed.
Attention:
To avoid damage to the hard disk drive connectors, make sure that
the server cover is in place and fully closed whenever you install or remove a
hard disk drive.
3. Pull the loops of the drive tray toward each other, and slide the drive into the
server until the drive connects to the backplate.
4. Release the loops of the drive tray.
5. Insert the filler panel into the bay to cover the drive.
Note:
If the server has a RAID controller or adapter installed, you might have to
reconfigure the disk arrays after installing hard disk drives. See the RAID
documentation on the IBM
System x Documentation
CD for information about RAID
adapters.
Chapter 4. Removing and replacing server components
49
Summary of Contents for x3550 - System - 7978
Page 1: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 36: ...18 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 46: ...28 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 202: ...184 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 49Y0122 Printed in USA 1P P N 49Y0122...