v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 7978 and 1913 server,” on page 29 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System event/error log message
Action
Fan
n
Failure
n
= the fan number
1. Make sure that the connector on the fan is not damaged.
2. Make sure that the fan connector on the system board is not
damaged.
3. Make sure that the fan is fully installed (press down on the
fan).
4. Reseat fan
n
.
5. Replace fan
n
.
Fan
n
Fault
n
= the fan number
1. Make sure that the connector on the fan is not damaged.
2. Make sure that the fan connector on the system board is not
damaged.
3. Make sure that the fan is fully installed (press down on the
fan).
4. Reseat fan
n
.
5. Replace fan
n
.
Hard Drive
n
Fault
n
= the hard disk drive number
1. Reseat hard disk drive
n
.
2. Replace hard disk drive
n
.
Hard drive
n
removal detected.
n
= the hard disk drive number
Reseat hard disk drive
n
.
Power supply
n
removed
n
= the power supply number
1. Reseat power supply
n
.
2. Replace power supply
n
.
3. Replace the power backplane.
Power supply
n
fault
n
= the power supply number
1. If the server power-on LED is lit, perform the following steps:
a. Reduce the server to the minimum configuration (see
“Power-supply LEDs” on page 140).
b. Reinstall the components you removed, one at a time,
restarting the server each time.
c. If the error reoccurs, the component you just reinstalled is
defective; replace the defective component.
2. Reseat the following components:
a. Power supply
n
b. (Trained service technician only) power backplane
3. Replace the components listed in step 2, one at a time, in the
order shown, restarting the server each time.
Power supply
n
AC power removed
n
= the power supply number
1. Make sure that the power cords are correctly connected to the
server and to a working electrical outlet.
2. (Trained service technician only) replace the power supply
n
.
3. (Trained service technician only) replace the power backplane.
Power supply
n
fan fault
n
= the power supply number
1. Make sure that there are no obstructions, such as bundled
cables, to the airflow on the power-supply fan.
2. Replace power supply
n
.
162
IBM System x3550 Type 7978 and 1913: Problem Determination and Service Guide
Summary of Contents for x3550 - System - 7978
Page 1: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 36: ...18 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 46: ...28 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 202: ...184 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 49Y0122 Printed in USA 1P P N 49Y0122...