v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 7978 and 1913 server,” on page 29 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
011-xxx-001
Failed COM2 serial port test.
1. Check the loopback plug that is connected to the
serial port.
2. (Trained service technician only) Replace the
system board.
030-xxx-000
Failed internal SAS interface test.
(Trained service technician only) Replace the system
board.
035-285-001
Adapter communication error.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-286-001
Adapter CPU test error.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-287-001
Adapter local RAM test error.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-288-001
Adapter NVSRAM test error.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-289-001
Adapter cache test error.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-292-001
Adapter parameter set error.
1. Update the RAID controller firmware.
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-230-001
Battery low.
Replace the battery module of the RAID controller.
035-231-001
Abnormal battery temperature.
Replace the battery module of the RAID controller.
035-230-001
Battery status unknown.
Replace the battery module of the RAID controller.
035-xxx-snn
Failed hard disk drive with ID nn on RAID
adapter in slot s.
1. Check the system-error log and replace any
indicated failing devices.
2. Reseat the disk with ID nn on adapter in slot s.
3. Replace the disk with ID nn on adapter in slot s.
035-xxx-099
No adapters were found.
If an adapter is installed:
1. Reseat the adapter.
2. Check the adapter cables to be sure they are
secure.
Chapter 5. Diagnostics
145
Summary of Contents for x3550 - System - 7978
Page 1: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 36: ...18 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 46: ...28 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 202: ...184 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 49Y0122 Printed in USA 1P P N 49Y0122...