Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 7978 and 1913 server,” on page 29 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
114
Adapter read-only memory error.
1. Reseat the adapter.
2. Replace the adapter.
129
Internal cache (L2) error.
1. (Trained service technician only) Reseat
microprocessor 1.
2. (Trained service technician only) Reseat
microprocessor 2 (if present).
3. (Trained service technician only) Replace the
following components one at a time, in the order
shown, restarting the server each time:
a. Microprocessor 1
b. Microprocessor 2 (if present)
c. System board
151
Real-time clock error.
1. Reseat the battery.
2. Clear CMOS. See “System-board switches and
jumpers” on page 11 for more information about
how to clear CMOS.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. System-board battery
b. (Trained service technician only) System
board
161
Real-time clock battery error.
1. Run the Configuration/Setup Utility program,
select
Load Default Settings
, and save the
settings.
2. Clear CMOS. See “System-board switches and
jumpers” on page 11 for more information about
how to clear CMOS.
3. Reseat the battery.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. System-board battery
b. (Trained service technician only) System
board
Chapter 5. Diagnostics
109
Summary of Contents for x3550 - System - 7978
Page 1: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 36: ...18 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 46: ...28 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 202: ...184 IBM System x3550 Type 7978 and 1913 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 49Y0122 Printed in USA 1P P N 49Y0122...