Configuring a controller for clustering
Complete the following steps to configure a controller for clustering.
Note:
For complete information on using the ServeRAID Manager program, see the
ServeRAID Manager online help.
1. Insert the
IBM ServeRAID Support
CD into the CD-ROM drive; then, turn on the
server. The ServeRAID Manager program starts.
2. If the ServeRAID Manager program detects unconfigured ServeRAID controllers
and ready drives, the program automatically starts the Configuration wizard, and
a window similar to the following opens. To exit the Configuration wizard, click
Cancel
; then, in the confirmation window, click
Yes
.
3. In the ServeRAID Manager tree, click the ServeRAID controller that you want to
configure.
Attention
Restore the ServeRAID controller to factory-default settings only once, when the controller
is first installed. This process removes all configuration information from NVRAM, including
the SCSI initiator IDs, the controller and partner names, and the array information.
This point is especially important if the Windows 2000 or Windows NT 4.0 system startup
drive is attached to the IBM ServeRAID controller. If this process occurs after the startup
drive array has been created, the array information will be removed, and the system will no
longer start in Windows 2000 or Windows NT 4.0.
If you already have logical drives defined that you want to keep, go to step 6. Steps 4 and 5
will cause loss of data by deleting all logical drives already defined.
Figure 34. Configuration wizard
112
IBM ServeRAID: User’s Reference, Version 5.10
Summary of Contents for ServeRAID
Page 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Page 10: ...x IBM ServeRAID User s Reference Version 5 10...
Page 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Page 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Page 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Page 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Page 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Page 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Page 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Page 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Page 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Page 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Page 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Page 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Page 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Page 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Page 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Page 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Page 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Page 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Page 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Page 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Page 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Page 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Page 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Page 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Page 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Page 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Page 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Page 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Page 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Page 225: ......
Page 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...