BCS
ECS
Explanation
Action
07
0C
Online/rebuild drives are not responding,
and a drive was found at the incorrect SCSI
ID.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
Note:
Pressing F4 might not correct the
problem. If you do not return the drives and
cables to the previous configuration, the
message might return.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
3. To modify the configuration and accept the
rearrangement of the physical drives, press
F6.
To exit without making changes, press F10.
07
1C
Online/rebuild and hot spare/standby
hot-spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
07
2C
Online/rebuild and ready/standby drives are
not responding, and a drive was found at
the incorrect SCSI ID.
07
3C
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, and a drive was found at the
incorrect SCSI ID.
07
4C
Online/rebuild drives are not responding,
and a drive was found at the incorrect SCSI
ID, and unidentified drives were found.
07
5C
Online/rebuild and hot spare/standby
hot-spare drives are not responding, a drive
was found at the incorrect SCSI ID, and
unidentified drives were found.
07
6C
Online/rebuild and ready/standby drives are
not responding, a drive was found at the
incorrect SCSI ID, and unidentified drives
were found.
07
7C
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, a drive was found at the
incorrect SCSI ID, and unidentified drives
were found.
07
18
Online/rebuild and hot spare/standby
hot-spare drives are not responding.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
To exit without making changes, press F10.
07
28
Online/rebuild and ready/standby drives are
not responding.
07
38
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding.
07
48
Online/rebuild drives are not responding,
and unidentified drives were found.
07
58
Online/rebuild and hot spare/standby
hot-spare drives are not responding, and
unidentified drives were found.
07
68
Online/rebuild and ready/standby drives are
not responding, and unidentified drives were
found.
07
78
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, and unidentified drives were
found.
09
00
No error occurred.
No action is required. Press F10 to exit without
making any changes.
154
IBM ServeRAID: User’s Reference, Version 5.10
Summary of Contents for ServeRAID
Page 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Page 10: ...x IBM ServeRAID User s Reference Version 5 10...
Page 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Page 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Page 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Page 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Page 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Page 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Page 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Page 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Page 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Page 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Page 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Page 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Page 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Page 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Page 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Page 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Page 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Page 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Page 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Page 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Page 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Page 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Page 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Page 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Page 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Page 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Page 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Page 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Page 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Page 225: ......
Page 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...