Selecting a RAID level and tuning performance
Disk arrays are used to improve performance and reliability. The amount of
improvement depends on the application programs that you run on the server and
the RAID levels that you assign to the logical drives.
Each RAID level provides different levels of fault-tolerance (data redundancy),
utilization of physical drive capacity, and read and write performance. In addition,
the RAID levels differ in regard to the minimum and maximum number of physical
drives that are supported.
When selecting a RAID level for your system, consider the following factors.
RAID level
Data
redundancy
Physical drive
capacity
utilization
Read
performance
Write
performance
Built-in
spare
drive
Min.
number
of drives
Max.
number
of drives
RAID level-0
No
100%
Superior
Superior
No
1
16
RAID level-1
Yes
50%
Very high
Very high
No
2
2
RAID level-1E
Yes
50%
Very high
Very high
No
3
16
RAID level-5
Yes
67% to 94%
Superior
High
No
3
16
RAID level-5E
Yes
50% to 88%
Superior
High
Yes
4
16
RAID level-00
No
100%
Superior
Superior
No
2
60
RAID level-10
Yes
50%
Very high
Very high
No
4
60
RAID
level-1E0
Yes
50%
Very high
Very high
No
6
60
RAID level-50
Yes
67% to 94%
Superior
High
No
6
60
Physical drive utilization, read performance, and write performance depend on the
number of drives in the array. Generally, the more drives in the array, the better the
performance.
Supported RAID levels
The ServeRAID controllers support RAID level-0, level-1, level-1E, level-5, level-5E,
level-00, level-10, level-1E0, and level-50.
The integrated RAID controllers support RAID level-1 only. The ServeRAID-5i
controller does not support RAID level-5E.
22
IBM ServeRAID: User’s Reference, Version 5.10
Summary of Contents for ServeRAID
Page 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Page 10: ...x IBM ServeRAID User s Reference Version 5 10...
Page 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Page 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Page 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Page 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Page 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Page 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Page 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Page 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Page 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Page 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Page 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Page 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Page 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Page 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Page 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Page 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Page 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Page 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Page 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Page 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Page 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Page 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Page 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Page 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Page 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Page 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Page 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Page 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Page 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Page 225: ......
Page 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...