Step 1520-21
Remove the CPU card(s), memory card(s), and Service Processor from the system.
Disconnect the FMC from the I/O Planar. Apply AC power to the system.
Is anything displayed on the operator panel?
NO
Go to “Step 1520-24” on page 2-24.
YES
Go to “Step 1520-22.”
Step 1520-22
Install the Service Processor on the I/O board.
Does the operator panel display "OK"?
NO
The service processor is defective. Replace it and go to "MAP 410:
Repair Checkout" in
Diagnostic Information for Multiple Bus Systems.
YES
Go to “Step 1520-23.”
Step 1520-23
Install the following parts in order. After each, verify that the operator panel displays
"OK." If not, the last part that was installed is defective. Replace it and go to "MAP
410: Repair Checkout" in
Diagnostic Information for Multiple Bus Systems.
1. Fan monitor control card.
2. CPU card.
3. Memory card.
If no defective FRU is found, go to “Step 1540-1” on page 2-26.
Chapter 2. Maintenance Analysis Procedures
2-23
Summary of Contents for RS/6000 H50
Page 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Page 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 131: ...Chapter 3 Error Code to FRU Index 3 51...
Page 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Page 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...