Gently pull the fan from the isolator.
Repeat for each isolator.
5. Remove the fan from the drawer.
Replacement:
Replace in the reverse order.
Rear Service Position
Notes:
1. Perform this operation only if the rails with the specially designed rear extenders
are installed in the rack to support the Enterprise Server H50 CPU Drawer.
2. Some operations in this procedure may require a step stool, depending on the
height of the individual. Either of the following may be used:
P/N 46G5947 Six foot step ladder
P/N 93G1147 Step stool
Attention: The Enterprise Server H50 CPU Drawer must be installed in the topmost
position of the rack unit, or have another drawer unit in the position immediately
above it to prevent the drawer from tipping out of the rack unit while in the service
position.
CAUTION:
The stabilizer must be firmly attached to the bottom rear of the rack to prevent
the rack from turning over when the drawers are pulled out of the rack. Do not
pull out or install any drawer or feature if the stabilizer is not attached to the
rack.
To gain access to the rear of the drawer, follow these steps:
1. Do the steps in the power off procedure as detailed in "Stopping the System
Unit" in chapter 2 of
RS/6000 Enterprise Server Model H50 User's Guide.
2. If the rack has a front door, open it.
3. Remove the two blower units from the top of the drawer.
4. Remove the media cover from the drawer.
5. Remove the DASD cover from the drawer.
6. Remove the nine brass screws from the media and DASD areas.
7. Remove the screws that hold the drawer to the rack unit.
Chapter 7. Removal and Replacement Procedures
7-23
Summary of Contents for RS/6000 H50
Page 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Page 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 131: ...Chapter 3 Error Code to FRU Index 3 51...
Page 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Page 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...