Step 1540-11
The last FRU installed or one of its attached devices is probably defective.
1. Make sure the diagnostic CD-ROM is inserted into the CD-ROM drive.
2. Turn the power off and remove the power cables.
3. Starting with the last installed adapter, disconnect one attached device and
cable.
4. Reinstall the power cables.
5. Turn the power on.
6. If the Console Selection screen is displayed, choose the system console.
7. After the keyboard indicator appears, press the F5 key on the directly-attached
keyboard or the number 5 key on an ASCII terminal keyboard.
8. Enter the appropriate password when prompted to do so.
Is the "Please define the System Console" screen displayed?
NO
Repeat this step until the defective device or cable is identified or all the
devices and cables have been disconnected.
If all the devices and cables have been removed, then one of the FRUs
remaining in the system unit is defective.
To test each FRU, exchange the FRUs in the following order:
1. Adapter (last one installed)
2. I/O board
If the I/O board or a network adapter is replaced, see notes on page
2-1.
3. Power supply.
If the symptom did not change and all the FRUs have been exchanged,
call your service support person for assistance.
If the symptom has changed check for loose cards, cables, and obvious
problems. If you do not find a problem return to “Step 1540-1” on
page 2-26 in this MAP and follow the instructions for the new symptom.
YES
The last device or cable that you disconnected is defective or if the last
device is the CPU card go to “Step 1540-3” on page 2-28.
Exchange the defective device or cable.
Go to "MAP 410: Repair Checkout" in the
Diagnostic Information for Mul-
tiple Bus Systems.
2-38
RS/6000 Enterprise Server Model H50 Installation and Service Guide
Summary of Contents for RS/6000 H50
Page 1: ...RS 6000 Enterprise Server Model H50 IBM Installation and Service Guide SA38 0547 00...
Page 16: ...xvi RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 30: ...1 12 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 131: ...Chapter 3 Error Code to FRU Index 3 51...
Page 160: ...5 18 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 245: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 290: ...B 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 305: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix C Modem Configurations C 15...
Page 312: ...C 22 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 316: ...D 4 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 324: ...X 8 RS 6000 Enterprise Server Model H50 Installation and Service Guide...
Page 326: ...X 10 RS 6000 Enterprise Server Model H50 Installation and Service Guide...