Installing or Removing Internal Drives
c. Locate the drive-release tab on the diskette drive.
d. Press the tab against the drive and hold it there; slide the drive into the bay
until it clicks into place.
4. If you want to install or remove any other options, do so now. Otherwise, go to
“Completing the Installation” on page 76.
Installing or Removing Drives in Bays 1 through 5 (Hard Disk Drives)
This section gives the procedure for installing a hard disk drive. If you want to
remove a drive, reverse the following steps.
Note: To minimize the possibility of damage to the hard disk drives when you are
installing a hard disk drive in a rack model, install the rack model in the rack
before installing the hard disk drives.
Attention: To avoid damage to a hard disk drive,
do not remove the drive from
the hot-swap bay until it has had time to spin down (approximately 30 seconds).
Handle the drive gently.
Before you begin
Read “Electrical Safety” on page 41 and “Handling Static-Sensitive Devices”
on page 42.
Read “Termination Requirements” on page 59
Your Netfinity 5000 server contains hardware that lets you replace a hard disk drive
without turning off the Netfinity 5000 server. These drives are known as
hot-swappable or hot-swap drives.
Each hot-swap drive that you plan to install must have a hot-swap-drive tray
attached. The drive must have a single connector attachment (SCA) connector.
Hot-swap drives come with the hot-swap-drive tray attached.
Chapter 4. Installing Options
63