Enable
supplemental
restart
policy
-
The
default
setting
is
yes.
When
set
to
yes
on
a
full
system
partition,
the
service
processor
restarts
the
server
when
the
operating
system
loses
control
and
either:
The
Use
OS-Defined
restart
policy
is
set
to
No.
OR
The
Use
OS-Defined
restart
policy
is
set
to
Yes
and
the
operating
system
has
no
automatic
restart
policy.
If
set
to
Yes
on
a
partitioned
system,
the
service
processor
restarts
the
system
when
the
system
loses
control
and
it
is
detected
by
service
processor
surveillance.
Refer
to
The
following
table
describes
the
relationship
among
the
operating
system
and
service
processor
restart
controls
in
a
full
system
partition.
OS
Automatic
reboot/restart
after
crash
setting
Service
processor
to
use
OS-Defined
restart
policy?
Service
Processor
Enable
supplemental
restart
policy?
System
response
None
No
1
No
None
No
1
Yes
1
Restarts
None
Yes
No
None
Yes
Yes
1
Restarts
False
2
No
1
No
False
2
No
1
Yes
1
Restarts
False
2
Yes
No
False
2
Yes
Yes
1
True
No
1
No
True
No
1
Yes
1
Restarts
True
Yes
No
Restarts
True
Yes
Yes
1
Restarts
1
Service
processor
default
2
AIX
default
In
a
partitioned
system,
the
service
processor’s
supplemental
restart
policy
is
the
only
setting
that
is
used,
as
shown
in
the
following
table:
Service
Processor
enable
supplemental
restart
policy
System
Response
No
Yes
(default)
Restarts
818
Eserver
pSeries
690
Service
Guide
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...