Error
Code
Description
Action/
Possible
Failing
FRU
101B
xxB1
BPA-B
/
EPO_SW
1.
Replace
the
UEPO
switch,
Location:
U1-V1
2.
Check
the
cable
from
BPC-B
to
the
UEPO
switch,
Location
U1-V1/Q2#
101C
0FB6
MCM
0
running
over
temperature
1.
Verify
that
the
MCM
at
U1.18-P1-C1
is
installed.
2.
Verify
that
there
are
no
airflow
problems
with
the
MCM
at
U1.18-P1-C1
or
its
heatsink.
3.
Verify
that
the
MCM
at
U1.18-P1-C1
is
installed
correctly
onto
the
processor
backplane.
4.
Call
service
support.
101C
0FC6
MCM
1
running
over
temperature
1.
Verify
that
the
MCM
at
U1.18-P1-C3
is
installed.
2.
Verify
that
there
are
no
airflow
problems
with
the
MCM
at
U1.18-P1-C3
or
its
heatsink.
3.
Verify
that
the
MCM
at
U1.18-P1-C3
is
installed
correctly
onto
the
processor
backplane.
4.
Call
service
support.
101C
0FD6
MCM
2
running
over
temperature
1.
Verify
that
the
MCM
at
U1.18-P1-C4
is
installed.
2.
Verify
that
there
are
no
airflow
problems
with
the
MCM
at
U1.18-P1-C4
or
its
heatsink.
3.
Verify
that
the
MCM
at
U1.18-P1-C4
is
installed
correctly
onto
the
processor
backplane.
4.
Call
service
support.
101C
0FE6
MCM
3
running
over
temperature
1.
Verify
that
the
MCM
at
U1.18-P1-C2
is
installed.
2.
Verify
that
there
are
no
airflow
problems
with
the
MCM
at
U1.18-P1-C2
or
its
heatsink.
3.
Verify
that
the
MCM
at
U1.18-P1-C2
is
installed
correctly
onto
the
processor
backplane.
4.
Call
service
support.
101C
1C06
Loss
of
airflow
in
processor
subsystem
resulting
in
over-temperature
Go
to
with
location
U1.18.
458
Eserver
pSeries
690
Service
Guide
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...