Error
Code
Description
Action/
Possible
Failing
FRU
20D0
9005
Subsystem
serial
number
field
is
empty
in
VPD
1.
If
the
location
code
starts
with
U1.17
or
U1.18,
the
problem
is
in
the
system
VPD
module
on
the
media
subsystem
operator
panel.
Replace
the
operator
panel;
do
not
swap
the
old
VPD
module
onto
the
new
operator
panel.
Call
service
support
for
instructions
on
programming
the
VPD
information
into
the
new
VPD
module.
2.
If
the
location
code
indicates
an
I/O
subsystem,
call
service
support.
20D0
9006
Duplicate
subsystem
serial
number
found
in
VPD
1.
If
the
location
code
starts
with
U1.17
or
U1.18,
the
problem
is
in
the
system
VPD
module
on
the
media
subsystem
operator
panel.
Replace
the
operator
panel;
do
not
swap
the
old
VPD
module
onto
the
new
operator
panel.
Call
service
support
for
instructions
on
programming
the
VPD
information
into
the
new
VPD
module.
2.
If
the
location
code
indicates
an
I/O
subsystem,
call
service
support.
20D0
9007
Invalid
subsystem
machine
type
and
model
information
in
VPD
1.
If
the
location
code
starts
with
U1.17
or
U1.18,
the
problem
is
in
the
system
VPD
module
on
the
media
subsystem
operator
panel.
Replace
the
operator
panel;
do
not
swap
the
old
VPD
module
onto
the
new
operator
panel.
Call
service
support
for
instructions
on
programming
the
VPD
information
into
the
new
VPD
module.
2.
If
the
location
code
indicates
an
I/O
subsystem,
call
service
support.
20D0
9008
Invalid
subsystem
serial
number
found
in
VPD
1.
If
the
location
code
starts
with
U1.17
or
U1.18,
the
problem
is
in
the
system
VPD
module
on
the
media
subsystem
operator
panel.
Replace
the
operator
panel;
do
not
swap
the
old
VPD
module
onto
the
new
operator
panel.
Call
service
support
for
instructions
on
programming
the
VPD
information
into
the
new
VPD
module.
2.
If
the
location
code
indicates
an
I/O
subsystem,
call
service
support.
20D1
0001
Failed
to
send
state-change
message
to
service
processor
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
20D1
0002
Failed
to
disable
heartbeat
alarm
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
496
Eserver
pSeries
690
Service
Guide
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...