Error
Code
Description
Action/
Possible
Failing
FRU
1016
xx41
Third
I/O
subsystem
in
primary
rack,
I/O
subsystem
backplane
2
fault
U1.1-P2
1016
xx43
Seeprom
fault
on
I/O
subsystem
backplane
2
in
third
I/O
subsystem
in
primary
rack
U1.1-P2
1016
xx51
Third
I/O
subsystem
in
primary
rack,
DASD
backplane
1
fault
U1.1-P3
1016
xx53
Seeprom
fault
on
DASD
backplane
1
in
third
I/O
subsystem
in
primary
rack
U1.1-P3
1016
xx61
Third
I/O
subsystem
in
primary
rack,
DASD
backplane
2
fault
U1.1-P4
1016
xx63
Seeprom
fault
on
DASD
backplane
2
in
third
I/O
subsystem
in
primary
rack
U1.1-P4
1016
xx71
Third
I/O
subsystem
in
primary
rack,
DASD
backplane
3
fault
U1.1-P5
1016
xx73
Seeprom
fault
on
DASD
backplane
3
in
third
I/O
subsystem
in
primary
rack
U1.1-P5
1016
xx81
Third
I/O
subsystem
in
primary
rack,
DASD
backplane
4
fault
U1.1-P6
1016
xx83
Seeprom
fault
on
DASD
backplane
4
in
third
I/O
subsystem
in
primary
rack
U1.1-P6
1017
1B17
Problem
with
fan
1
in
fourth
I/O
subsystem
(no
IBF
installed)
in
primary
rack
1.
DCA-1
Location:
U1.13-V1
2.
Fan
1
Location:
U1.13-F1
1017
1B27
Problem
with
fan
2
in
fourth
I/O
subsystem
(no
IBF
installed)
in
primary
rack
1.
DCA-2
Location:
U1.13-V2
2.
Fan
2
Location:
U1.13-F2
1017
1C06
Loss
of
airflow
in
fourth
I/O
subsystem,
no
IBF
location:
U1.13
Go
to
1017
6014
Overcurrent
or
overvoltage
problem
with
3.3V
in
fourth
I/O
subsystem,
no
IBF
Go
to
1017
6024
Overcurrent
or
overvoltage
problem
with
5.0V
in
fourth
I/O
subsystem,
no
IBF
Go
to
1017
6034
Overcurrent
or
overvoltage
problem
with
2.5V
in
fourth
I/O
subsystem,
no
IBF
Go
to
1017
6044
Overcurrent
or
overvoltage
problem
with
12.0V
in
fourth
I/O
subsystem,
no
IBF
Go
to
1017
6054
Overcurrent
or
overvoltage
problem
with
-12.0V
in
fourth
I/O
subsystem,
no
IBF
Go
to
1017
6814
Overcurrent
or
overvoltage
problem
with
3.3V
in
fourth
I/O
subsystem,
no
IBF
Go
to
1017
6824
Overcurrent
or
overvoltage
problem
with
5.0V
in
fourth
I/O
subsystem,
no
IBF
Go
to
1017
6834
Overcurrent
or
overvoltage
problem
with
2.5V
in
fourth
I/O
subsystem,
no
IBF
Go
to
Chapter
5.
Error
Code
to
FRU
Index
439
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...