Error
Code
Description
Action/
Possible
Failing
FRU
B1xx
4633
System
power
control
network
(SPCN)
failure
Action:
This
error
code
may
be
informational,
or
it
may
indicate
a
failure
in
the
SPCN
firmware
update.
Before
changing
any
parts,
examine
word
13
in
the
service
processor
error
log
entry,
or
bytes
68
and
69
in
the
AIX
error
log
entry.
For
detailed
instructions
on
finding
word
13
in
the
service
processor
error
log
entry,
or
bytes
68
and
69
in
the
AIX
error
log
entry,
see
error
code
If
the
error
code
(word
11
value)
is
B1394633,
and
the
word
13
value
is
2309xxxx,
this
is
an
informational
message.
No
action
is
required
by
the
customer
or
service
representative.
All
of
the
following
values
of
word
13
(or
bytes
68
and
69)
indicate
a
failure
of
an
SPCN
firmware
update:
A704:
The
SPCN
code
update
has
been
interrupted;
the
SPCN
firmware
update
terminates.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Action:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Power
on
the
system
and
restart
all
partitions;
the
SPCN
code
update
will
restart
and
run
in
the
background.
A70E:
SPCN
(system
power
control
network)
flash
update
was
successful.
Actions:
This
is
an
informational
message;
no
action
is
required
by
the
customer
or
service
representative.
It
indicates
that
the
SPCN
code
flash
update
was
successful.
A710:
SPCN
command
″
RLI
″
failed;
this
indicates
a
loss
of
communication
with
the
SPCN
controller.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Action:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Remove
the
350V
of
power
from
the
system
by
putting
the
UEPO
switch
into
the
OFF
position.
Place
the
UEPO
switch
into
the
ON
position.
Wait
five
minutes.
Use
the
HMC
to
power
on
the
system
.
Restart
at
least
one
partition.
The
SPCN
code
update
will
run
in
the
background.
If
this
error
code
(word
13
value)
reoccurs,
contact
service
support.
A711:
SPCN
command
″
DDB
″
failed;
this
indicates
a
loss
of
communication
with
the
SPCN
controller.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Actions:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Remove
the
350V
of
power
from
the
system
by
placing
the
UEPO
switch
into
the
OFF
position.
Place
the
UEPO
switch
into
the
ON
position.
Wait
five
minutes.
Use
the
HMC
to
power
on
the
system.
Restart
at
least
one
partition.
The
SPCN
code
update
will
run
in
the
background.
If
this
error
code
(word
13
value)
reoccurs,
contact
service
support.
A712:
SPCN
command
″
QFS
″
failed.
This
is
logged
in
the
AIX
error
log
as
a
firmware
event.
Actions:
Stop
all
partitions.
Use
the
HMC
to
power
down
the
system.
Remove
the
350V
of
power
from
the
system
by
placing
the
UEPO
switch
into
the
OFF
position.
Place
the
UEPO
switch
into
the
ON
position.
Wait
five
minutes.
Use
the
HMC
to
power
on
the
system.
Restart
at
least
one
partition.
The
SPCN
code
update
will
run
in
the
background.
If
this
error
code
(word
13
value)
reoccurs,
contact
service
support.
A713:
No
power
subsystem
code
LID
was
found
in
the
firmware
image;
the
FRU
firmware
update
terminates.
This
is
logged
in
the
AIX
error
log
as
a
sysplanar0
error.
Actions:
Contact
service
support.
A715:
A
bad
power
subsystem
code
LID
was
found
in
the
firmware
image;
the
FRU
firmware
update
terminates.
This
is
logged
in
the
AIX
error
log
as
a
sysplanar0
error.
Actions:
Contact
service
support.
Error
code
B1xx
4633
continues
on
to
the
next
row.
754
Eserver
pSeries
690
Service
Guide
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...