Error
Code
Description
Action/
Possible
Failing
FRU
1016
F4x6
Hardware
configuration
does
not
support
N-mode
power.
Call
Service
Support
1016
F516
An
N+1
boundary
(DCA
or
fan)
has
dropped
to
N-mode
status
in
the
third
I/O
subsystem,
location:
U1.1.
This
is
normally
an
informational
message.
It
should
be
accompanied
by
other
error
codes
that
more
precisely
indicate
where
the
failure
is.
Examine
the
service
processor
error
log.
If
there
are
no
other
power-related
error
codes
(in
the
time
frame
in
which
this
code
was
generated)
in
the
service
processor
error
log,
the
FRU
indicated
with
this
error
code,
if
any,
should
be
replaced.
1016
F526
An
N+1
boundary
(DCA
or
fan)
has
dropped
to
N-mode
status
in
the
third
I/O
subsystem,
location:
U1.1.
This
is
normally
an
informational
message.
It
should
be
accompanied
by
other
error
codes
that
more
precisely
indicate
where
the
failure
is.
Examine
the
service
processor
error
log.
If
there
are
no
other
power-related
error
codes
(in
the
time
frame
in
which
this
code
was
generated)
in
the
service
processor
error
log,
the
FRU
indicated
with
this
error
code,
if
any,
should
be
replaced.
1016
xx11
third
I/O
subsystem
in
primary
rack,
DCA-1
U1.1-V1
1016
xx13
Seeprom
fault
on
DCA-1
in
third
I/O
subsystem
in
primary
rack
U1.1-V1
1016
xx15
Third
I/O
subsystem
in
primary
rack,
DCA-1,
cable
fault
Go
to
with
these
pairs
of
location
codes:
1.
U1.1-V1/Q1
and
U1.35-P2-X3/Q5
2.
U1.1-V1/Q2
and
U1.35-P1-X3/Q5
1016
xx17
Problem
with
fan
1
and
fan
3
in
third
I/O
subsystem
in
primary
rack
1.
DCA-1
Location
U1.1–V1
2.
Fan
1,
Location
U1.1–F1
3.
Fan
3,
Location
U1.1–F3
1016
xx21
Third
I/O
subsystem
in
primary
rack,
DCA-2
U1.1-V2
1016
xx23
Seeprom
fault
on
DCA-2
in
third
I/O
subsystem
in
primary
rack
U1.1-V2
1016
xx25
Third
I/O
subsystem
in
primary
rack,
DCA-2,
cable
fault
Go
to
with
these
pairs
of
location
codes:
1.
U1.1-V2/Q1
and
U1.35-P2-X3/Q6
2.
U1.1-V2/Q2
and
U1.35-P1-X3/Q6
1016
xx27
Problem
with
fan
2
and
fan
4
in
third
I/O
subsystem
in
primary
rack
1.
DCA-2
Location
U1.1–V2
2.
Fan
2,
Location
U1.1F2
3.
Fan
4,
Location
U1.1–F4
1016
xx31
Third
I/O
subsystem
in
primary
rack,
I/O
subsystem
backplane
1
fault
U1.1-P1
1016
xx33
Seeprom
fault
on
I/O
subsystem
backplane
1
in
third
I/O
subsystem
in
primary
rack
U1.1-P1
438
Eserver
pSeries
690
Service
Guide
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...