Replacement
or
New
Installation
Note:
This
procedure
is
to
be
performed
only
by
trained
service
personnel.
1.
Go
to
and
install
the
MCM/L3
module
short-circuit
test
tool.
Use
the
test
tool
during
the
MCM
replacement
procedure
to
ensure
that
the
MCMs
are
installed
without
a
short
circuit.
If
you
install
an
MCM
and
encounter
a
short
circuit,
the
MCM
you
installed
must
be
replaced.
2.
If
installing
a
new
MCM,
insert
the
new
actuation
bolt
supplied
with
the
new
MCM
module
and
move
the
actuation
bolt
and
spring
assembly
to
the
up
position
and
hand-tighten
to
hold
the
assembly
in
the
up
position.
Perform
a
general
cleaning
operation,
using
a
sash
brush,
(
not
the
one
included
with
the
FRU
kit)
and
vacuum
cleaner
(see
for
the
part
numbers),
to
remove
any
accumulated
dust
and
debris
that
has
settled
in
the
processor
subsystem.
Hold
the
vacuum
hose
near
the
brush
to
remove
any
debris
the
brush
generates.
3.
Loosen
the
captive
bolt
in
the
center
of
the
protective
cover
and
remove
the
cover
from
the
new
MCM
module,
as
shown
in
the
following
illustration.
4.
If
you
are
installing
MCMs
with
the
aluminum
heatsink,
go
to
substep
If
you
are
installing
MCMs
with
the
copper
heatsink,
do
the
following:
Note:
The
field
restocking
plan,
is
to
replace
the
1.7
GHz
copper
heatsink
MCM
(factory
installed)
with
a
1.7
GHz
aluminum
heatsink
MCM.
a.
Ensure
that
the
stiffener
located
on
the
backplane
is
aluminum
and
not
plastic.
b.
Insert
the
two
steel
alignment
rods
into
the
aluminum
backplane
stiffener.
c.
Ensure
that
the
locking
cams
located
on
the
aluminum
backplane
stiffener
are
in
the
open
position
d.
Grasp
the
module
across
the
narrow
span
of
the
heatsink
cap.
Align
the
corner
chamfer
(flat
corner)
on
the
MCM
module
or
the
pass
through
to
match
the
outline
on
the
backplane.
e.
Align
the
two
steel
alignment
rods
with
the
clearance
holes
located
on
each
side
of
the
MCM.
f.
Insert
the
MCM
clearance
holes
over
the
two
steel
alignment
rods
and
slide
the
MCM
module
into
the
socket,
and
maintain
pressure
while
closing
both
locking
cams.
g.
Use
an
5-mm
locking
socket
wrench
to
secure
the
locking
cams
over
the
MCM.
h.
Go
to
substep
5.
Grasp
the
module
across
the
narrow
span
of
the
heatsink
cap.
Align
the
corner
chamfer
(flat
corner)
on
the
MCM
module
or
the
pass
through
to
match
the
outline
on
the
backplane.
Attention:
Verify
that
the
guide
pins
protrude
above
the
connectors.
Carefully
push
the
MCM
module
into
the
socket.
If
your
system
has
the
plastic
backplane
stiffener,
use
an
8-mm
locking
socket
wrench
to
secure
the
locking
cams
over
the
MCM.
Be
sure
to
maintain
pressure
on
the
MCM
when
securing
both
locking
cams.
6.
Loosen
the
actuation
bolt
at
the
rear
of
the
MCM
module.
7.
Push
the
actuation
bolt
in
and
slide
the
spring
plate
assembly
to
the
down
position.
886
Eserver
pSeries
690
Service
Guide
Summary of Contents for eserver pSeries 690
Page 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 2: ......
Page 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Page 12: ...x Eserver pSeries 690 Service Guide...
Page 14: ...xii Eserver pSeries 690 Service Guide...
Page 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Page 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Page 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Page 430: ...414 Eserver pSeries 690 Service Guide...
Page 798: ...782 Eserver pSeries 690 Service Guide...
Page 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Page 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Page 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Page 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Page 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Page 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Page 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Page 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Page 1090: ...1074 Eserver pSeries 690 Service Guide...
Page 1094: ...1078 Eserver pSeries 690 Service Guide...
Page 1122: ...1106 Eserver pSeries 690 Service Guide...
Page 1124: ...1108 Eserver pSeries 690 Service Guide...
Page 1132: ...1116 Eserver pSeries 690 Service Guide...
Page 1133: ......
Page 1134: ...Printed in U S A February 2004 SA38 0589 05...