Table
38.
Symptom-to-FRU
index
(continued)
Problem
indicator
Component
Possible
cause
Possible
solutions
Unable to access
drives
Drives and
fibre-channel
loop
Incorrect storage
expansion
enclosure ID
settings
Ensure that the fibre-channel
optical cables are undamaged
and properly connected. Check
the storage expansion enclosure
ID settings.
Note:
For information on how to
change the storage expansion
enclosure ID if required, refer to
the online Help in the DS Storage
Manager GUI.
ESM failure
Replace one or both ESMs.
Contact an IBM technical support
representative.
Drive or drives
failed
Replace failed drive or drives.
Drive is not certified Check the DS4000 product Web
site for the correct drive option
P/N or FRU P/N certified for your
DS4000 storage subsystem.
Random errors
Subsystem
Midplane failure
Have the midplane replaced.
Contact an IBM technical support
representative.
Hard disk drive
not visible in RAID
Several CRUs
Drive or drives
failed
Replace failed drive or drives.
management
software
FC cable failed
Replace FC cable.
SFP failed
Replace SFP.
ESM failure
Replace ESM.
Midplane failure
Have the midplane replaced.
Contact an IBM technical support
representative.
Incorrect firmware
version
Verify that the storage subsystem
has been upgraded to the correct
firmware version. Refer to
Table 40 on page 136.
Parts
listing
Figure 60 on page 132 and the following table provide a parts listing for the
EXP810.
Chapter 6. Hardware maintenance
131
Summary of Contents for DS4000 EXP810
Page 2: ......
Page 67: ...ds470067 Figure 20 Installing a bezel Chapter 2 Installing the EXP810 39...