v
The
dc
power
supply
and
fan
unit
LED
and
dc
Power
LED
are
on
and
Fault
LED
is
off
- Go to step 17.
16. Perform the following task or task(s) to resolve the problem:
v
Ensure the disconnect device is set to the ON position.
v
Ensure that the power switch is turned to the ON position.
v
Ensure that there is power at the power source and no circuit breaker has
tripped.
v
Ensure that the power cord is working and fully seated into the power
source and the power supply and fan unit dc socket.
v
Reinstall the dc power supply and fan unit.
If the above tasks do not resolve the problem, contact IBM Customer and
Technical Support.
17. Complete any remaining Recovery Guru procedures, if needed.
18. Check the status of each storage expansion enclosure in the storage
subsystem.
19. Do any components have a Needs Attention LED?
v
Yes
- Select the Recovery Guru toolbar button in the Subsystem
Management Window and complete the recovery procedure. If a problem is
still indicated, contact IBM Customer and Technical Support.
v
No
- Go to step 20.
20. Create, save, and print a new storage subsystem profile.
Replacing
an
Environmental
Service
Module
(ESM)
This section describes the removal and replacement procedure for a failed hot-swap
ESM. Always verify the FRU part number of the replacement ESM to verify that it is
compatible with the existing ESM in the EXP810 chassis. Inserting non-compatible
ESM FRU may cause lost of data availability.
The EXP810 storage expansion enclosures support the ESM auto code
synchronization functionality. When a new ESM is installed into an existing storage
expansion enclosure in a DS4000 storage subsystem that supports ESM auto code
synchronization, firmware is automatically synchronized in the new ESM with the
firmware in the existing ESM. This function requires that the DS4000 storage
subsystem be defined in the Enterprise Management window of the DS Storage
Manager client program installed in a management station. Additionally, the DS
Storage Manager client program must be opened and running, or the IBM DS
Storage Manager Event Monitor service must be running when the new ESM is
inserted.
Refer to the
DS
Storage
Manager
Version
10
Installation
and
Host
Support
Guide
for your operating system for more information on how to start this service. Do not
perform to the following steps until you have installed the DS Storage Manager
client program, defined the affected DS4000 storage subsystem in the Enterprise
Management window, and either have the DS Storage Manager client program
running or the Event Monitor service started.
Chapter 5. Installing and replacing components
115