Link
Rate
LEDs
Two on = 4 Gbps
One on = 2 Gbps
Figure
52.
Link
rate
LEDs
If both Link Rate indicator LEDs are on, the data transfer rate is set for 4
Gbps. If one Link Rate indicator light is on, the data transfer rate is set for 2
Gbps.
2. Is the data transfer rate set correctly?
v
Yes
- Go to step 8 on page 104.
v
No
- Go to step 3 to change the setting.
Attention:
When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling static-sensitive
devices, see “Handling static-sensitive devices” on page 30.
3. Complete the power-off sequence described in “Turning off the EXP810” on
page 80 ensuring that the DS4000 storage subsystem is turned off before any
attached storage expansion enclosures.
4. Locate the Link Rate switch. Figure 52 shows the location of the Link Rate
indicator light on the front of the command module.
Chapter 5. Installing and replacing components
103